ASSESSMENT OF REMAINING LIFE
Direct condition assessments through thickness measurements and coatings grading can confirm the current state of an asset but without the context of an operation history and future use can be of little value in confirming future life. In this case the asset owner was faced with large 70 year old cast iron water tanks that were integral to his process but very disruptive to inspect. CAPCIS designed an uncertainty based degradation model that calculated probability distributions for internal and external corrosion based on a knowledge of the construction, operating environments, maintenance history and the behaviour of the materials used. Initial corrosion performance data was taken from literature and the model used to facilitate a workshop discussion with operations, maintenance and contractor staff that enabled direct input into the model, the identification of sensitive parameters and the further work required to close these down. At this early stage the future life predictions gave the Owner sufficient confidence to move forward with his plans .

CAPCIS CARE Flyer


© CAPCIS Ltd 2008, All Rights Reserved | Disclaimer | Terms of Use | Privacy Policy | Copyright Statement